User's Manual

Troubleshooting Guide for the DLT2500/DLT2700 Mini-Library
6-8 DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem
__________________________Note _____________________________
Slot 0 lights in all error conditions to indicate an error occurred. It is not
a Slot Select indicator in this case.
____________________________________________________________
After you clear the error try loading and unloading cartridges to verify operation.
6.6.2 DLT2700 Loader Fault Description
A loader fault indicates the DLT2700 detected a fatal error in the loader transfer
assembly or in the tape drive. In some loader transfer assembly errors, the subsystem
retries the error three times before indicating failure. All loader faults cause the Loader
Fault light and an associated subcode to light.
Loader Fault indicates errors in the loader transfer assembly, controller module, or
drive. The suspected fault location is indicated by the following slot lights:
Slots 4 and 0a controller module
Slots 5 and 0a loader transfer assembly
Slots 6 and 0drive
__________________________Note _____________________________
Error lights do not blink. During hardware failures, the controller module
determines action.
____________________________________________________________
6.6.2.1 Clearing a DLT2700 Loader Fault
When a loader fault occurs, the Load/Unload and Eject lights are on. When you press
the Load/Unload button, the DLT2700 attempts to clear the error. When you press
Eject, the receiver opens to let you access the magazine.
6.7 Power Problems
If the Power On light is not on, or your system does not recognize the
DLT2500/DLT2700 subsystem:
= Ensure the power plug is secure.
= Verify with your system manager that the subsystem configuration is correct.