User's Manual
Sense Key Information 
DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem C-5 
47 00 SCSI parity error 
48 00 IDE Message received 
49 00 Invalid Message Error 
4E 00 Overlapped commands attempted 
•  Volume Overflow (Dh): 
no additional sense code 
• Miscompare (Eh): 
no additional sense code 
_________________________ Note _____________________________ 
The Filemark/EOM/ILI bits may be set even though ASC/ASCQ = 00 00: 
___________________________________________________________ 
(1) FM, EOM, ILI bit may be set with no sense key (0) and ASC/ASCQ = 00 00 
(2) FM, EOM, ILI bit may be set with recovered error (1) and ASC/ASCQ = 00 00 
(3) FM, EOM, ILI bit may be set with medium error (3) and ASC/ASCQ = 00 00 
(4) EOM bit is set at Volume Overflow (Dh) and ASC/ASCQ = 00 00 
(5) FM (byte 2, bit 7), EOM (byte 2, bit 6), and ILI (byte 2, bit 5) are fields in request 
data. (See figure on REQUEST SENSE Data.) 