A-4 DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem 
A.2.1 Identifying the Correct AC Power Cord 
________________________ Warning ______________________  
Do not attempt to modify or use an external 100 - 115 VAC power cord 
for 220 - 240 VAC input power. Modifying the power cord can cause 
personal injury and severe equipment damage. 
_______________________________________________________  
An AC power cord was supplied with your unit. Carefully inspect it and make sure that 
it is the correct one for your country or region based on the criteria listed below. If you 
feel the supplied AC power cord is not correct, contact your authorized Quantum 
service representative. 
The AC power cord used with this equipment must meet the following criteria: 
1.  UL and CSA Certified cordage rated for use at 250 VAC with a current rating that 
is at least 125% of the current rating of the product. In Europe, the cordage must 
have the <HAR> mark. 
2.  The AC plug must be terminated in a grounding-type male plug designed for use in 
your country. It must also have marks showing certification by an agency 
acceptable in the country. 
3.  The connector at the product end must be an IEC type CEE-22 female connector. 
4.  The cord must be no longer than 14.5 feet (4.5 meters). 
__________________________ Note ________________________  
The power cord should be a minimum of 18/3 AWG, 60ยบC, Type SJT 
or SVT. 
_______________________________________________________  