User's Manual
DLT2000 SCSI Interface 
DLT2000/DLT2700 Cartridge Tape Subsystem 8-35 
status. The sense key is set to ILLEGAL REQUEST and the additional sense code is set 
to INVALID FIELD IN CDB. 
If the target does not support a parameter code within this page then it will not return 
any data associated with this parameter. 
SP 
Saving log parameters is not supported and shall be always zero. 
If the SP bit is set, the command is terminated with CHECK CONDITION status with 
the sense key set to ILLEGAL REQUEST, and an additional sense code of INVALID 
FIELD IN CDB. 
PC 
The Page Control field defines the type of parameter values to be returned: 
PC Type of Parameter Values
Threshold Values
Cumulative Values
Default Threshold Values
Default Cumulative Values
00b
01b
10b
11b
Figure 8-18 LOG Page Control Definitions  
The Default Threshold Values are the maximum values that each parameter can attain. 
The Current Cumulative Values are the values computed since the last reset of the 
device (either by power-cycling, BUS DEVICE RESET, or SCSI RESET). 
The Default Cumulative Values are the values to which each parameter gets initialized 
on a reset condition as described previously. Default values are zero. 
By default Current threshold values = Default threshold values. 
_________________________ Note _____________________________ 
All types of Parameter values are changeable through LOG SELECT. 
___________________________________________________________ 
Page Code 
The Page Code field identifies which log page is being requested by the initiator. If the 
page is not supported then the command terminates with a CHECK CONDITION status 
with the sense key set to ILLEGAL REQUEST and an additional sense code of 
INVALID FIELD IN CDB. Supported pages are as follows: 