User's Manual
DLT2000 SCSI Interface 
8-34 DLT2000/DLT2700 Cartridge Tape Subsystem 
8.4.8 LOG SENSE (4Dh) 
Bit
76543210
0 Operation Code (4Dh)
Logical Unit Number (0) PPC SP(0)
PC Page Code
Byte
(MSB)
Parameter Pointer
(LSB)
Unused
Reserved
Reserved
1
Flag Link
(MSB)
Allocation Length
(LSB)
Reserved
2
Reserved
3
4
5
6
7
8
9
Figure 8-17 LOG SENSED CDB 
LOG SENSE allows the host to retrieve statistical information maintained by the device 
about its own hardware or the installed media. It is a complementary command to LOG 
SELECT. 
PPC 
The Parameter Pointer Control bit must be zero. A Parameter Pointer Control bit of 
zero indicates that the parameter data requested from the device will start with the 
parameter code specified in the Parameter Pointer field and return the number of bytes 
specified in the Allocation Length field in ascending order of parameter codes from the 
specified log page. A PPC bit of zero and a Parameter Point field of zero causes all 
available parameter data for that page code to be returned to the initiator. 
__________________________Note _____________________________ 
The current implementation of the Read/Write Compression Page does not 
support a parameter pointer other than zero. 
____________________________________________________________ 
If PPC bit is set or the Parameter Pointer is larger than the highest numbered parameter 
on the page, then the target will terminate the command with CHECK CONDITION 










