User's Manual
DLT2000 SCSI Interface 
8-30 DLT2000/DLT2700 Cartridge Tape Subsystem 
8.4.7.1 Operation of LOG SELECT 
The purpose of the LOG SELECT command is to allow the initiator to modify and 
initialize parameters within the logs supported by the device. 
There are two ways to initialize the log parameters. First, set the PCR bit in the LOG 
SELECT CDB; this clears all parameters. Secondly, individual pages can be cleared by 
specifying the log page and the parameter value as the log parameters. The following 
pages can be cleared in this manner. 
Page Code Page Description
02h
03h
32h
Write Error Counter Page
Read Error Counter Page
Compression ratio page
Figure 8-14 Clearable Log Pages   
If multiple pages are sent during this DATA OUT phase, they must be sent in ascending 
order according to page code. Otherwise the command will terminate with a CHECK 
CONDITION status with the sense key set to ILLEGAL REQUEST and an additional 
sense code of INVALID FIELD IN PARAMETER LIST. The same status will be 
returned if an unsupported Page Code appears in any header, or if the specified page 
cannot be cleared. 










