User's Manual
DLT2000 SCSI Interface 
DLT2000/DLT2700 Cartridge Tape Subsystem 8-125 
Fixed 
The fixed bit specifies both the meaning of the Transfer Length field and whether fixed-
length or variable-length blocks are to be transferred. If the Fixed bit is set to zero, 
Variable Block mode is selected. A single block is transferred from the initiator and is 
written to the logical unit beginning at the current logical tape position. Upon successful 
termination, the tape is logically positioned after this block (EOM/P side). The Transfer 
Length specifies the number of bytes that the drive handshakes out from the initiator. 
If the Fixed bit is set to one, the Transfer Length field specifies the number of blocks to 
be transferred to the host beginning at the current tape position. This form of WRITE is 
valid only if the logical unit is currently operating in Fixed Block mode, in other words, 
when it has been instructed to use fixed-length blocks with MODE SELECT. The 
current block length is the block length defined in the MODE SELECT command. 
Upon termination, the tape is logically positioned after these blocks. 
Transfer Length 
This field contains the length of the data transfer in bytes or blocks, depending on 
whether Fixed or Variable block mode is selected. 
If the Transfer Length is zero, no data is transferred and the current position on the 
logical unit is not changed. 
Exception Conditions 
If EOT is detected while writing, the drive will finish writing any buffered data. The 
command terminates with CHECK CONDITION status. Within the Sense data, the 
EOM bit is set, the Sense Key field is set to NO SENSE, and the Additional Sense 
Code and Additional Sense Code Qualifier fields are set to EOM/P detected. The drive 
attempts to complete any subsequent writes, returning a CHECK CONDITION status in 
each case. 
If the drive encounters the physical EOM when attempting write, CHECK 
CONDITION status is returned. Within the Sense data, the EOM and Valid bits are set, 
and the Sense Key field is set to Volume Overflow The Information fields contain the 
residue count and the Additional Sense Code and Additional Sense Code Qualifier 
fields are set to EOM/P Detected. The tape is physically positioned at EOM/P. 