Parameter List—Block Descriptor Field Descriptions
The following table defines the fields in the Parameter List block descriptor.
Field
Name
Bytes
Description
Density
Code
0 The following values define this field:
Hex Code Meaning
00 Default format (DDS)
7F No-op
25 DDS-3
26 DDS-4
47 DAT 72
The drive will accept any of these density codes as valid when sending a Block
Descriptor. The density code does not dictate the format written on the media, the
drive detects the media type and writes the correct format for that media.
Selecting a Density Code value not listed above, or not supported by the drive,
will result in a Check Condition. The sense data is set to Invalid field in parameter
list.
Block
Length
5-7 If this field is nonzero, it indicates the length of the fixed-length block to be read or
written when the Fixed bit is set in a READ or WRITE command. (It is acceptable
to set the Fixed bit to 0.). The default is 512-byte blocks, which may be changed
at any time by the host with a MODE SELECT command.
If this field is zero, variable-length block mode is specified, and the Fixed bit in the
READ or WRITE command must be 0. The Block Length in a READ or WRITE
command may be set in a range from 1 to 16 MB (as specified in the READ
BLOCK LIMITS command.)
Mode Page Format
The following table shows the generic Mode Page format.
Byte
Bits
7 6 5 4 3 2 1 0
0 0 0 | Page Code
1 Page Length
2
.
.
.
n
Mode Parameters