User's Guide
Page 72 DDS-4 SCSI Interface Manual, Rev. B
Parameter Code Length Name
07
3
Minutes since last cleaning
08 3 Power on time (minutes)
09 3 Cylinder on time (minutes)
0A 2 Cleaning Cartridge count
0B 2 Reserved
0C 2 Reserved
0D 2 Reserved
0E 2 Reserved
0F 2 Reserved
10 2 Reserved
11 1 Reserved
12 1 Reserved
Completion Status
The Completion Status for the LOG SENSE command is shown in the following
table.
Code Message Description
00h Good Status
02h Check
Condition
Extended Sense Byte 02h:
Code Message Description
02h Not Ready No cartridge is inserted in the drive.
04h Hardware Error Parity error on SCSI bus or drive
hardware failure detected.
05h Illegal Request
• The CDB contains an invalid bit.
• The Page Code in the Log Page Header
specifies an unsupported log page.
• The parameter pointer is invalid.
06h Unit
• Cartridge was changed prior to accepting
Attention this command
• The drive was reset prior to this
command.