User's Guide

Page 72 DDS-4 SCSI Interface Manual, Rev. B
Parameter Code Length Name
07
3
Minutes since last cleaning
08 3 Power on time (minutes)
09 3 Cylinder on time (minutes)
0A 2 Cleaning Cartridge count
0B 2 Reserved
0C 2 Reserved
0D 2 Reserved
0E 2 Reserved
0F 2 Reserved
10 2 Reserved
11 1 Reserved
12 1 Reserved
Completion Status
The Completion Status for the LOG SENSE command is shown in the following
table.
Code Message Description
00h Good Status
02h Check
Condition
Extended Sense Byte 02h:
Code Message Description
02h Not Ready No cartridge is inserted in the drive.
04h Hardware Error Parity error on SCSI bus or drive
hardware failure detected.
05h Illegal Request
The CDB contains an invalid bit.
The Page Code in the Log Page Header
specifies an unsupported log page.
The parameter pointer is invalid.
06h Unit
Cartridge was changed prior to accepting
Attention this command
The drive was reset prior to this
command.