Release Notes
Changes and Updates 9
AMU
Version 3.10E
Table 9 Changes in version 3.10E
Related Ticket Explanation of Changes
New Function: AMU version will be shown in the AMU log 
New Function: The AMU checks for configurations with wrong load modules 
(only functional working combinations will be allowed and started)
ET90532 New Function: Drive serial number.  
Assign serial numbers for the drives. ACI applications can access this 
information. The "Drive Configuration" dialog box (Admin->Configuration and 
double-click on any drive) was extended. Now at the bottom of this box is an 
additional field "Drive's serial number" and additional button "HW info" -- 
"Hardware information" can be seen.  
Field "Drive's serial number" is available for reading/changing and it can be 
used to assign any sequence up to 50 characters.  
Button "HW Info" will be enabled only for DCI drives and in this release its 
functionality is not implemented.
ET36851 New Function: Additional pushbutton to reset Trace Buffer  
Now a "Clear" button can be seen in the "Trace" window and it can be used to 
reset the trace buffer. 
ET43402 New Function: AMU should use old clean cartridges first  
Now the AMU will look at the use-count of clean cartridges to select those with 
the highest use-count (but not higher than watermark)
ET44142 New Function: Repeat the NTFY 1339 in intervals until communication is OK. 
After a link between AMUs in a Dual-AMU configuration was lost, each AMU 
would issue notification 1339. Now this notification can be repeated in intervals 
until communication is restored. To configure this, an additional field "Dual 
AMU link lost" in the "Process Configuration" dialog box (menu Admin -> 
Process Configuration can be used. The default value for this field is blank, 
which is the old behavior (without repeat). Any number from 1 to 120 minutes 
can be entered in this field. Changes (after hitting OK) will take place 
immediately.
ET44151 New Function: Configure time interval clean pool notification 
Now a time interval for notification 1312 "Please insert clean cartridges for 
CleanPool: XXXX" can be configured. Default value is 5 min (previous 
behavior). It is possible to set up any value from 1 to 120 min. Zero will mean 
that a repeat of this notification is suppressed.
Changed Behavior: Scratch Pool Dialog, graphical configuration  
Checkbox "Scratch" will be read-only
Changed Behavior: Cleaning commands will be added to the "operator" menu.  
Cleaning commands (Insert Clean, Eject Clean, Clean Drive) are duplicated 
from "Commands" menu to the "Operations" menu.
ET65747} Changed Behavior: AmuLog.exe, missing function quit  
AmuLog.exe needs to be left by pressing 'Q' key (previously you Ctrl + Break 
had to press)