Installation manual
9
Weatherhood Installation
36" (1m)
recommended min.
36" (1m)
recommended min.
6' (2m)
recommended min.
18" (460mm) min.
18" (460mm) min.
OUTSIDE CORNER
INTAKE
EXHAUST
INSIDE CORNER
Outside Weatherhoods
The fixed-cover hoods have a built in bird screen with a
1/4” (6mm) mesh to prevent foreign objects from entering
the ductwork.
Locating the Intake Weatherhood (if applicable)
• At least 6' (2 m) from the exhaust weatherhood
• At least 6' (2 m) away from dryer vents and furnace
exhaust (medium or high efficiency furnaces)
• At least 3' (1 m) from the corner of the building
• Do not locate in a garage, attic or crawl space
Locating the Exhaust Weatherhood
• At least 6' (2 m) from the ventilation air intake
• At least 18" (460mm) above ground or above the depth
of expected snow accumulation*
• At least 3' (1 m) away from the corner of the building*
• Not near a gas meter, electric meter or a walkway
where fog or ice could create a hazard
• Not into a garage, workshop or other unheated space.
When installing the weatherhood, its outside perimeter
must be sealed with exterior caulking.
Grilles
Techgrille
We recommend the use of high mounted wall returns with
grilles. The Techgrille is a round, fully adjustable grille
which provides superior, quiet exhaust. The Techgrille is
available 4”, 5” 6” and 8” (100 mm, 125 mm, 150 mm and
200 mm) sizes.
Part# 99-EAG4 4” diameter Techgrille
Part# 99-EAG5 5” diameter Techgrille
Part# 99-EAG6 6” diameter Techgrille
Part# 99-EAG8 8” diameter Techgrille
Kitchen Exhaust Grille
Do not connect the kitchen exhaust duct to a range hood.
Instead, the exhaust should be mounted high on the wall
at least 4 feet (1.2 m) horizontally away from the stove. A
“flip-up”, 6 x 10 (150 x 250 mm) rectangular kitchen grille
with removable grease filter is available (Part No. 10-002)
Part# 10-002 6” x 10” Kitchen grille
Part# 10-002-2 Replacement Grease Filter
Removable filter