User's Manual
2.2 Using a Qflash T5d-R with an FW8R or FW7Q
receiver as a remote
Press the mode button, on the Qflash t5d-R, then use the up or down
buttons to select Wireless Remote Group 1 or Wireless Remote
Group 2.
The Qflash T5d-R may display a message that it needs a signal from the
Local flash to activate this mode. The message will disappear when you
set up the Co-Pilot
Set the channel on the FW8R or FW7Q. There are eight channels
available, 0 through 7.
NOTE: Set all zones to ON.
2.3 Using a Non Quantum flash as a remote
Connect a flash unit to a FW8 or FW10w receiver. Set the channel on the
receiver, to the same channel set on Co-Pilot.
Use the ZONE switches to select the remote group. Zone 1 ON = Remote
Group R1, Zone 2 ON = Remote Group R2, Zone 3 ON = Remote Group R3.
NOTE: When using a non Quantum flash the Co-Pilot will provide a sync
signal to fire the flash, but will not control the exposure. The MAN-TTL mode
switch for this Group must be set to M.
3 .2 Local Qflash T5d-R connected
When a Qflash T5d-R is connected to the Co-Pilot ACCY connector, Group R3
becomes the Local ratio control
Remotes will operate in Groups R1, R2 only.
RATIO / MANUAL POWER SETTINGS – this control adjusts the ratio of the
local Qflash T5d-R, when the Qflash is in QTTL mode. Ratio settings can be
set from -2
7
to +2.
MODE switch – this control is disabled when a Qflash T5d-R is connected to
the Co-Pilot. The MODE button on the local Qflash T5d-R overrides the
mode setting.
2 Setting up the Remote Groups
A remote Group can consist of
Quantum Trio set to Remote Group R1, R2, R3
Qflash T5d-R set to Wireless Group R1, R2. When used with
an FW8R or FW7Q receiver.
Any non Quantum flash that can be triggered by an external sync
signal from an FW8R or FW10w.
Note: All channels must be set to the same channel number.
2.1 Using a Quantum Trio as a remote
Press the mode button, on the Trio, use the left or right arrow buttons to
select Wireless Remote Group. Press one of the soft keys to choose R1,
R2, or R3.
Press the RADIO softkey to set the channel. There are eight channels
available, 0 through 7.
NOTE: There is no need to set the ZONES when using Wireless Remote
Groups with the Trio.
3 Co-Pilot setup
The Co-Pilot can control the exposure of three Remote Groups (R1, R2, and
R3) or two Remote Groups (R1, R2) and a local Qflash T5d-R.
A Remote Group can consist of a Quantum Trio, Qflash T5d-R with an FW8R
or FW7Q receiver, or any non Quantum flash that can be triggered by a sync
signal. The Co-Pilot will fire a non Quantum flash but not control it’s exposure.
3 .1 No Local Qflash T5d-R connected
Each Remote Group has two controls.
R1, R2, and R3 (when no Qflash T5d-R is connected to the ACCY connector)
RATIO / MANUAL POWER SETTINGS – this control adjusts the exposure of
the Remote Group. Ratio settings can be set from -2
7
to +2. Manual power
settings can be set from 1/16- to 1/1. This control also has an OFF position.
When set in the OFF position the flash in the Remote Group will not fire.
MODE switch – this control sets the mode of the Remote Group to M (manual)
or TTL. If the Remote Group is a Quantum Trio or Qflash T5d-R
Note : When using a non Quantum flash as a Remote Group set the MODE
switch to M.
MODE
SET
REMOTE GROUP R1
AUTO F 5.6
7
3.6 –32 FT ISO 200
FIRE OPT SAVE RADIO
+
-
R1 R2 R3 / LOCAL
M TTL M TTL M TTL
R1 R2 R3 / LOCAL
M TTL M TTL M TTL
WIRELESS GROUP R1
TO ACTIVATE CONTROL FROM
LOCAL QFLASH TURN LOCAL
QFLASH OFF THEN ON