User guide
Table Of Contents
- 1 Safety Information
- 2 Product Information
- 3 Mechanical Installation
- 4 Electrical Installation
- 4.1 Electrical connections/ Power connections
- 4.2 Ground connections
- 4.3 AC supply requirements
- 4.4 Line reactors
- 4.5 Auxiliary AC supply and connections
- 4.6 Separating the Auxiliary Supply
- 4.7 Control 120 Vac supply
- 4.8 Control 24 Vdc supply
- 4.9 Cable and fuse size ratings
- 4.10 External suppressor resistor
- 4.11 Ground leakage
- 4.12 EMC (Electromagnetic compatibility)
- 4.13 Serial communications connections
- 4.14 Shield connections
- 4.15 Control connections
- 4.16 General
- 4.17 Connecting an encoder
- 5 Getting Started
- 5.1 Understanding the display
- 5.2 Keypad operation
- 5.3 Menu 0 (sub block)
- 5.4 Pre-defined sub blocks
- 5.5 Menu 0 (linear)
- 5.6 Menu structure
- 5.7 Advanced menus
- 5.8 Saving parameters
- 5.9 Restoring parameter defaults
- 5.10 Displaying parameters with non- default values only
- 5.11 Displaying destination parameters only
- 5.12 Parameter access level and security
- 5.13 Serial communications
- 6 Basic parameters
- 7 Running the Motor
- 8 Optimization
- 9 SMARTCARD Operation
- 9.1 Introduction
- 9.2 Easy saving and reading
- 9.3 Transferring data
- 9.3.1 Writing to the SMARTCARD
- 9.3.2 Reading from the SMARTCARD
- 9.3.3 Auto saving parameter changes
- 9.3.4 Booting up from the SMARTCARD on every power up (Pr 11.42 (SE09, 0.30) = boot (4))
- 9.3.5 Booting up from the SMARTCARD on every power up (Pr xx.00 = 2001)
- 9.3.6 Comparing drive full parameter set with the SMARTCARD values
- 9.3.7 7yyy / 9999 - Erasing data from the SMARTCARD
- 9.3.8 9666 / 9555 - Set / clear SMARTCARD warning suppression flag
- 9.3.9 9888 / 9777 - Set / clear the SMARTCARD read only flag
- 9.4 Data block header information
- 9.5 SMARTCARD parameters
- 9.6 SMARTCARD trips
- 10 Onboard PLC
- 11 Advanced Parameters
- 11.1 Menu 1: Speed reference
- 11.2 Menu 2: Ramps
- 11.3 Menu 3: Speed feedback and speed control
- 11.4 Menu 4: Torque and current control
- 11.5 Menu 5: Motor and field control
- 11.6 Menu 6: Sequencer and clock
- 11.7 Menu 7: Analog I/O
- 11.8 Menu 8: Digital I/O
- 11.9 Menu 9: Programmable logic, motorized pot and binary sum
- 11.10 Menu 10: Status and trips
- 11.11 Menu 11: General drive set-up
- 11.12 Menu 12: Threshold detectors, variable selectors and brake control function
- 11.13 Menu 13: Position control
- 11.14 Menu 14: User PID controller
- 11.15 Menus 15, 16 and 17: Solutions Module slots
- 11.16 SM-I/O120V Solutions Module parameter settings
- 11.17 Menu 18: Application menu 1
- 11.18 Menu 19: Application menu 2
- 11.19 Menu 20: Application menu 3
- 11.20 Menu 21: Second motor parameters
- 11.21 Menu 22: Additional Menu 0 set-up
- 11.22 Menu 23: Header selections
- 11.23 Advanced features
- 12 Technical Data
- 12.1 Drive technical data
- 12.1.1 Power and current ratings
- 12.1.2 Power dissipation
- 12.1.3 AC Supply requirements
- 12.1.4 Supply types
- 12.1.5 SCR bridge AC Supply
- 12.1.6 Auxiliary AC supply
- 12.1.7 Line reactors
- 12.1.8 Temperature, humidity and cooling method
- 12.1.9 Storage
- 12.1.10 Altitude
- 12.1.11 IP Rating
- 12.1.12 Corrosive gasses
- 12.1.13 RoHS compliance
- 12.1.14 Vibration
- 12.1.15 Start up time
- 12.1.16 Output speed range
- 12.1.17 Accuracy
- 12.1.18 Acoustic noise
- 12.1.19 Overall dimensions
- 12.1.20 Weights
- 12.2 Cable and fuse size ratings
- 12.3 Optional external EMC filters
- 12.1 Drive technical data
- 13 Diagnostics
- 14 UL Information
- List of tables
- Index

Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running the
Motor
Optimization
SMARTCARD
Operation
Onboard
PLC
Advanced
Parameters
Technical
Data
Diagnostics
UL
Information
Quantum MP User Guide 115
Issue: A3 www.emersonct.com
Parameter
Range(
) Default()
Type
7.01 T5/6 analog input 1 {in02, 0.82} ±100.00% RO Bi NC PT
7.02 T7 analog input 2 {in03, 0.83} ±100.0% RO Bi NC PT
7.03 T8 analog input 3 {in04, 0.84} ±100.0% RO Bi NC PT
7.04 Power circuit temperature -128°C to 127°C RO Bi NC PT
7.08 T5/6 analog input 1 scaling 0 to 40.000 1.000 RW Uni US
7.09 T5/6 analog input 1 invert OFF (0) to On (1) OFF (0) RW Bit US
7.10 T5/6 analog input 1 destination Pr 0.00 to 22.99 Pr 1.36 RW Uni PT US
7.11 T7 analog input 2 mode 0 to 9 6 RW Uni US
7.12 T7 analog input 2 scaling 0 to 40.000 1.000 RW Uni US
7.13 T7 analog input 2 invert OFF (0) to On (1) OFF (0) RW Bit US
7.14 T7 analog input 2 destination Pr 0.00 to 22.99 Pr 1.37 RW Uni PT US
7.15 T8 analog input 3 mode {in01, 0.81} 0 to 9 Eur: 8 USA:6 RW Txt US
7.16 T8 analog input 3 scaling 0 to 40.000 1.000 RW Uni US
7.17 T8 analog input 3 invert OFF (0) to On (1) OFF (0) RW Bit US
7.18 T8 analog input 3 destination
Pr 0.00 to Pr 22.99
Pr 0.00 RW Uni PT US
7.19 T9 analog output 1 source Pr 3.02 RW Uni PT US
7.20 T9 analog output 1 scaling 0.000 to 40.000 1.000 RW Uni US
7.21 T9 analog output 1 mode 0 to 3 0 RW Txt US
7.22 T10 analog output 2 source Pr 0.00 to Pr 22.99 Pr 4.02 RW Uni PT US
7.23 T10 analog output 2 scaling 0.000 to 40.000 1.000 RW Uni US
7.24 T10 analog output 2 mode
0 to 3
0 RW Txt US
7.28 T7 analog input current loop loss 2 OFF (0) to On (1) RO Bit NC PT
7.29 T8 analog input current loop loss 3 OFF (0) to On (1) RO Bit NC PT
7.30 T5/6 analog input 1 offset ±100.00% 0.00 RW Bi US
7.31 T7 analog input 2 offset ±100.0% 0.0 RW Bi US
7.32 T8 analog input 3 offset ±100.0% 0.0 RW Bi US
7.34 SCR / Thyristor junction temperature 0 to 150°C RO Uni NC PT
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save










