Technical data
DAT 72 (DDS Gen5) 36/72 GBYTE
i
Configuration for other operating systems
Switch 5 to 8 = OFF, ON, ON, OFF (Novell)
Switch 5 to 8 = ON, OFF, OFF, OFF (DEC UNIX)
Jumper settings
SCSI address (SCSI 0, SCSI 1, SCSI 2 and SCSI 3 jumpers)
SCSI address SCSI 1 SCSI 2 SCSI 4 SCSI 8
address 15 + + + +
address 14 – + + +
address 13 + – + +
address 12 – – + +
address 11 + + – +
address 10 – + – +
address 9 + – – +
address 8 – – – +
address 6 – + + –
address 5 + – + –
address 4 – – + –
address 3 + + – –
address 2 – + – –
address 1 + – – –
address 0 – – – –
+ = installed
– = not installed
Default setting:
Jumpers SCSI 1 and SCSI 2 inserted, jumpers SCSI 0 and SCSI 3 not inserted = address 6
i
SCSI address 7 is always reserved for the SCSI controller.
Termination power (TERM PWR jumper)
The TERM PWR jumper sets the power supply for the terminating resistors on the SCSI bus. The
terminating resistors can be provided with power by the drive or the SCSI bus.
Termination power via SCSI bus = TERM PWR not inserted
Termination power via drive = TERM PWR inserted
Default setting:
TERM PWR jumper not inserted = power supply from SCSI bus
Parity checking (jumper PE)
The jumper PE is preset to "Parity Checking Enabled".
Parity check enabled = PE inserted
Parity check disabled = PE not inserted
Default setting:
PE inserted = Parity check enabled
16 - English A26361-H939-Z100-1-7419