Technical data

DAT 72 (DDS Gen5) 36/72 GBYTE
Setting streamer
!
Please note the information provided in the chapter "Important notes" in the Operating
Manual of the computer or in the manual "Safety and Ergonomics".
The DAT drive can be set by means of jumpers and switches.
PE
SCSI 2
SCSI 3
SCSI 1
SCSI 0
TERM PWR
ON
12
34
5678
9
10
Position of plug-in jumpers and switches on the back and bottom of the drive
Default settings of the jumpers
TERM PWR = not inserted (Termination Power from SCSI bus)
SCSI 1, SCSI 2
SCSI 0, SCSI 3
= inserted
= not inserted (SCSI address 6)
PE = inserted (Parity check enabled)
Default settings of the switches
1° and
= ON (Data compression enabled, software control possible)
3 = ON (media recognition enabled)
4 = ON (the drive runs a self-test diagnostic sequence (POST = Power-On Self Test) for
about 5 sec.)
5 to 8 = ON, ON, OFF, ON (switch 7 = OFF, default block size 0 for Windows and UNIX)
9 = ON (the drive is capable of operating in Wide (16-bit) SCSI mode)
10 = ON (drive supplies Standard Inquiry String (SEAGATE DAT))
A26361-H939-Z100-1-7419 English - 15