Operating instructions
SECTION THREE
INSTALLATION
After choosing a suitable location
(see previous section)
install the unit as follows:
Remove the wiring box cover by gently pushing the
side retaining lugs inwards and lift off.
The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm
2
gauge is used. A isolating should be installed to switch
the power to the unit ON & OFF. This allows the sensor to be easily switched off when not
required or for maintenance purposes.
Unfasten the screw on the top of the floodlight. Install the halogen bulb, making sure not
to touch the bulb with bare hands. It is suggested that the bulb is handled using a dry
cloth.
Ensure the bulb is correctly fitted in the lampholder before use.
Re-attach the front cover, do not overtighten the fixing screw.
Mark the position of the fitting holes from the wall bracket.
Drill the holes. Insert the rawl plugs into the holes.
Fix the bracket to the wall.
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or
switching off the circuit breaker before proceeding with the installation.
CONNECTION
PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING.
Connect the cable to the terminal block on the unit as follows (see connection diagram):
NEUTRAL (Blue) N
EARTH (Green/Yellow)
LIVE (Brown) L
Ensure that the connections are secure.
For details of override connections, please see later sections.
Secure the cable using the cord grip provided.
Re-attach the wiring box cover, ensuring a weatherproof seal is obtained.
Fix the floodlight to the bracket
Retaining Lugs Insert small
screwdriver
and gently
push and lift
cover off.
Wiring Box Cover