Specifications

754HF1/180/300 300W Security Floodlight Installation Instructions
9 of 20
© Clipsal Australia Pty Ltd
3.2 Adjustment Knobs
PIR TIMER
If the unit is set to AUTOMATIC MODE, the PIR TIMER setting
controls how long the unit remains illuminated after motion has
been detected (and after all motion has ceased). The minimum
time (fully anti-clockwise) is approximately 5 seconds, whilst
the maximum time (fully clockwise) is approximately 5 minutes.
Set the control to the desired setting between these limits.
SUNSET TIMER
If the unit is set in SUNSET SWITCH MODE, the SUNSET
TIMER setting controls how long the COURTESY LIGHT
remains illuminated after dusk. The Courtesy Light can be
set to a dim level (set by the DIM CONTROL) for a period
between 1 and 8 hours. Set the SUNSET TIMER CONTROL
to the desired setting between these limits.
LUX CONTROL
The LUX setting controls the level of darkness required for the
unit to start operating. The setting is best achieved using the
following procedure: Set the LUX setting fully anti-clockwise.
The unit will now start operating at dusk. If you require the light
to activate earlier, wait until the ambient light level reaches
the level of darkness at which you wish the lamp to become
operative. Then SLOWLY rotate the control in a clockwise
direction until a point is reached where the lamp illuminates.
Leave the control at this set point.
DIM CONTROL
The DIM setting controls the COURTESY LIGHT in SUNSET
SWITCH MODE. The DIMMER is adjustable from 0% (OFF)
to 95% of the light output. When set, the DIMMER will activate
the light at dusk each evening. It will then stay illuminated at
this low level of courtesy lighting until the sensor is activated.
When movement is detected the lamp will go to full power for
the time period set by the PIR TIMER control. After the set
time has elapsed the light level will return to the dimmed light
level until the SUNSET TIMER period has elapsed.
8hrs1hr