3.0 Commissioning Procedure
3.1 Walk Testing Procedure
1. The sensor will rotate from left to right. Adjust the sensor to point in the
desired direction (see Diagram A and H for the different sensor patterns and
lens masking).
2. Set the two adjustment knobs on the sides of the sensor (Diagram C) to the
following positions:
3. The unit will now operate during daytime as well as at night, illuminating the lamp
for approximately five seconds each time. This allows testing to be carried out to
establish the best position for the sensor.
4. Switch on the mains power. The lamp will immediately illuminate as the unit goes
through its ‘warm-up’ period. After approximately one to two minutes the lamp will
extinguish. Try to remain outside the detection area during the warm-up period.
5. Walk across the detection area approximately five metres from the unit. As you
cross a detection ‘zone’ the lamp will illuminate. Now stand still until the lamp
extinguishes (this should take approximately five seconds).
6. Start moving again. As you cross each ‘zone’ the lamp will illuminate. Repeat the
above, walking at various distances and angles to the unit. This will help you to
establish the detection pattern.
7. The units sensor module can be adjusted horizontally from left to right. If the
detection area is too small for your requirements, try turning the sensor head.
This can increase the coverage distance or will reduce the range should a smaller
coverage area be required (see Diagram G to see how to adjust the floodlight
beam to suit).
PIR TIMER
5 Seconds Fully anti-clockwise
SUNSET TIMER
1 Hour Fully anti-clockwise
LUX
Full Sunlight Fully clockwise
DIM
0% (Off) Fully anti-clockwise