Specifications

754HF1/180/300 300W Security Floodlight Installation Instructions
5 of 20
© Clipsal Australia Pty Ltd
2.0 Installation Procedure
Unit is for outdoor use only. Unit must be mounted on a non-flammable surface as a
fixed luminaire, and is not suitable for portable use. The unit can get very hot during
use. Ensure the unit has cooled before handling. Ensure adequate ventilation space
is allowed between the unit and any object above, in front or to either side of the unit.
Suggested space is 0.5m above, 0.3m to either side and 1.0m in front. Do not attempt
to install during wet weather conditions.
All electrical installations must be carried out by a Licensed Electrician.
2.1 Selecting a Location
1. The motion detector has a number of detection zones, at various vertical and
horizontal angles as shown (see Diagram A).
2. A moving human body needs to cross/enter one of these zones to activate the
sensor. The best all-round coverage is achieved with the unit mounted at the
optimum height of 2.5m.
3. Careful positioning of the sensor will be required to ensure optimum performance.
See Diagram B detailing detection range and direction.
4. The sensor is more sensitive to movement ACROSS its field of vision than to
movement directly TOWARDS (see Diagram B). Therefore position the unit so
that the sensor looks ACROSS the likely approach path.
5. Avoid positioning the sensor where there are any sources of heat in the detection
area (extractor fans, tumble dryer exhausts etc.) including any other light sources
such as other security lighting.
6. Reflective surfaces (i.e. pools of water or white painted walls) and overhanging
branches may cause false activation under extreme conditions.
7. During extreme weather conditions the motion sensor may exhibit unusual
behaviour. This does not indicate a fault with the sensor. Once normal weather
conditions return, the sensor will resume normal operation.