300W Security Floodlight 754HF1/180/300 180° Outdoor Motion Sensor ® Installation Instructions Please leave these instructions at the installation site.
754HF1/180/300 300W Security Floodlight Installation Instructions Contents 1.0 Introduction............................................................................................... 3 1.1 Features............................................................................................. 3 1.2 Wireless Alarm Upgrade Kit............................................................... 4 2.0 Installation Procedure.............................................................................. 5 2.
754HF1/180/300 300W Security Floodlight Installation Instructions 1.0 Introduction Thank you for purchasing the 754HF1/180/300 Outdoor Infrascan Motion Detector. The Motion Detector unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the spotlights will illuminate for a user-determined time period. An integrated daylight sensor ensures nightonly operation.
754HF1/180/300 300W Security Floodlight Installation Instructions 1.2 Wireless Alarm Upgrade Kit Did you know that a Wireless RF Accessory Kit (754RFKIT) is available for this unit? The upgrade kit is battery powered and retro-fittable - no extra wiring is required. Simply plug in the external RF Transmitter to the floodlight and the portable Chime Receiver will alert you to any external activation of the floodlight.
754HF1/180/300 300W Security Floodlight Installation Instructions 2.0 Installation Procedure Unit is for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed luminaire, and is not suitable for portable use. The unit can get very hot during use. Ensure the unit has cooled before handling. Ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side and 1.0m in front.
754HF1/180/300 300W Security Floodlight Installation Instructions 2.2 Mounting the Unit 1. Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top (see Diagram D). 2. Mark the position of the fitting holes. Drill the holes. Insert wallplugs into the holes. 3. BEFORE SECURING THE WALLPLATE TO THE WALL PIERCE AND PASS THE CABLE THROUGH THE GROMMET. 4. Attach the wall plate to the wall (see Diagram E). 2.3 Electrical Connections 1.
54HF1/180/300 300W Security Floodlight Installation Instructions 2.4 Halogen Lamp Replacement - Caution Replacement lamp type is 240V mains halogen 300W R7s cap floodlight lamp. 1. Isolate the mains supply. 2. Unfasten the clip on the top of the floodlight glass shield. Open the glass cover. The cover is mounted on hinges and will swing open. 3. To remove existing lamp, depress then lift one end of the lamp to remove. 4. Install new lamp, making sure not to touch the lamp with bare hands.
754HF1/180/300 300W Security Floodlight Installation Instructions 3.0 Commissioning Procedure 3.1 Walk Testing Procedure 1. The sensor will rotate from left to right. Adjust the sensor to point in the desired direction (see Diagram A and H for the different sensor patterns and lens masking). 2.
754HF1/180/300 300W Security Floodlight Installation Instructions 3.2 Adjustment Knobs PIR TIMER If the unit is set to AUTOMATIC MODE, the PIR TIMER setting controls how long the unit remains illuminated after motion has been detected (and after all motion has ceased). The minimum time (fully anti-clockwise) is approximately 5 seconds, whilst the maximum time (fully clockwise) is approximately 5 minutes. Set the control to the desired setting between these limits.
754HF1/180/300 300W Security Floodlight Installation Instructions 3.3 Setting up for Automatic Operation 1. When walk tests are complete, the unit can be switched to automatic operation. 2. The PIR TIMER setting controls how long the unit remains illuminated following activation and after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approximately five minutes. Set the control to the desired setting between these limits. 3.
754HF1/180/300 300W Security Floodlight Installation Instructions 3.5 Special Functions MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the MANUAL OVERRIDE MODE. The light can be activated AT NIGHT by using the internal wall switch / circuit breaker. Switch the internal wall switch / circuit breaker OFF/ON within 2 seconds.
754HF1/180/300 300W Security Floodlight Installation Instructions 4.0 Detection Range / Setting Controls A B TOP VIEW Less Sensitive 180° SIDE VIEW More Sensitive 2.
754HF1/180/300 300W Security Floodlight Installation Instructions 5.
754HF1/180/300 300W Security Floodlight Installation Instructions 6.0 Connection Diagram F Wall Plate Cable Entry Neutral Blue/Black (N) Earth Green/Yellow (E or ) Active/Live Brown/Red (L) Connect the mains cable to N,E and L connections in the terminal block Match the three pins on the unit to the wall plate.
754HF1/180/300 300W Security Floodlight Installation Instructions 7.0 Angle Adjustment G The Floodlight can be adjusted to angle the beam to cover the required area. 20° 30° 70° 70° CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY. 8.
754HF1/180/300 300W Security Floodlight Installation Instructions 9.0 Troubleshooting PROBLEM SOLUTION Lamp stays ON all the time at night. The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from “seeing” anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was caused by false activation. PIR keeps activating for no reason / at random.
754HF1/180/300 300W Security Floodlight Installation Instructions 10.0 Technical Specifications Operating Voltage 240V~ 50Hz a.c.
754HF1/180/300 300W Security Floodlight Installation Instructions 11.0 Warranty 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Clipsal Australia Pty Ltd of 33-37 Port Wakefield Road, Gepps Cross, South Australia 5094.
754HF1/180/300 300W Security Floodlight Installation Instructions 13.
754HF1/180/300 300W Security Floodlight Installation Instructions 14.