User manual
8
5.1 Illumination modes
We can choose between 3 different illumination modes for the product selection pushbuttons.
5.2 Procedure for changing the illumination mode
With the machine turned off, simultaneously press the one-coffee and continuous coffee keys of the group 1 (left). Without releasing the
buttons, press the mains power switch and wait for all three lights to begin blinking, indicating that you have entered into the illumination
selection mode.
• Press the one-coffee pushbutton to select “Mode1”.
• Press the continuous coffee pushbutton to select “Mode 2”.
• Press the two-coffee pushbutton to select “Mode 3”.
Selecting Pushbutton LED Illumination Mode
5.
b. LED MODE 2
By default, all the pushbuttons are illuminated.
When a button is pressed, it remains illuminate
and the others turn off.
c. LED MODE 3
By default, all the pushbuttons are illuminated.
When a pushbutton is pressed, it will turn off
and the others will remain illuminated.
a. LED MODE 1
By default, all the pushbuttons are unlit. When
we press a button that key lights up and the
others remain unlit.
Alarm and Indication Signals
6.
Flowmeter Alarm
Boiler Refilling Indicator
Boiler Heating Element On
Boiler water level Alarm
Alarms
Indications