User's Manual

80-J7615-1 Rev. A MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION 8-5
Installing the TT210 Terminal on Reefers TT210 Input Power Options for Refrigerated Trailers
Carrier Standard Controller units must have an EEPROM chip loaded with the DataTRAK
software version 3.30 or higher.
To check the software version, follow these steps.
1. Turn ON power.
2. Wait for self-test to finish.
3. Press UNIT DATA.
4. Press the DOWN ARROW until the software version displays.
5. If the software version is not 3.30 or higher, change the EEPROM.
Themo King units must have i-Boxes installed with minimum 5308 software and
communication setting set for third-party communications.
TT210 Input Power Options for Refrigerated Trailers
The TT210 power input option for refrigerated trailers is 7-way, reefer, and integrated solar
input power.
SETPOINT
BOX TEMPERATURE
FUNCTION
CHANGE
ENTER
UNIT
DATA
PRETRIP
CHECK
AUTO S/S
CONTINUOUS
MANUAL
DEFROST
08AAA_027
COOLCOOL
START/STOP
Reefer
TT210
Terminal
7-way data
and power
Refer Specific
Cable
(TK or Carrie
r)
Reefer Power
and Data
Via Bluetooth
to TT210
Configuration
T
ool (on laptop)
Optional
Door/Aux
Sensors
DRAFT