Antenna-to-antenna separation requirements – According to KDB 447498, collocated
antennas are permitted without test as long as the antenna-to-antenna separation distance
is at least 20 cm. Smaller separation distances are permitted without test as long as specific
conditions are met in which combined MPE values are under the FCC’s limits. These
conditions are described in the calculations in the section Simultaneous RF Exposure
Evaluation Guidelines for Collocated Transmitters Allowable through a Class I Permissive
Change.