Product Specs
Packet Modem Spec Rev6.doc 30 06/09/00
• The baud rate is user configurable from between 300 and 115.2Kbps. The
baud rate is adjustable in software.
• In case of a reboot (due to fatal errors or any other reason), the DCD line
will be set inactive so that the user application can detect a reset
condition and take the necessary action.
• Functionally the Data Port integrates AT Commands and Alert Messages as well as
Application Packet Data PPP traffic.
• The Data Port provides limited deconfliction of PPP vs. AT Commands and Alerts by
queuing alerts to the user, if control port is not in use. The User Application is
required to deconflict AT commands sent to the module if no control port is used.
6.3.3 DB 25 Data and Control Port Pinouts:
Table 1 Interface Connector Pinout
Pin
number
Signal Name Signal
level
Direction
User <-> Module
Description
1 Chassis
Ground
- Chassis Ground Isolated chassis
ground
2 DP_TXD RS-232 DTE -> DCE Data port TXD
3 DP_RXD RS-232 DTE <- DCE Data port RXD
4 DP_RTS RS-232 DTE -> DCE Data port RTS
5 DP_CTS RS-232 DTE <- DCE Data port CTS
6 DSR RS-232 DTE <- DCE Module DSR
7 Ground Ground Ground return Ground return
8 DP_DCD RS-232 DTE <- DCE Data port DCD
9 DC_POWER 5.2V-11V Module Power
10 DC_POWER 5.2V-11V Module Power
11 Ground Ground Ground return Ground return
12 DP_DTR RS-232 DTE -> DCE Control port DTR
13 Reserved Reserved Reserved Control port CTS,