Instruction Manual

QTI Page 9 of 13 Revision: A
Form #: 30Z0250 Effective Date: 16 December 2009
Poll for a new message:
NEW<CR>
Returns:
RXM TT III SS<CR>, where TT is the message type,III
is the ID, and SS is the status code
Returns if no new message:
RXM<CR>
PSH….Get/Set to push new messages out the serial port.
1 = ON (New messages pushed out the serial port when received)
0 = OFF (must poll for new messages)
Get PUSH mode:
PSH<CR>
Returns:
PSH Z<CR>
Set PUSH mode:
PSH Z<CR>
Returns:
PSH Z<CR>
PWR…Get/Set the transmitter power level.
1 = 1 watt transmit power at least
2 = 2 watt transmit power at least
Get power level:
PWR<CR>
Returns:
PWR Z<CR>
Set power level:
PWR Z<CR>
Returns:
PWR Z<CR>
RCV ….. Get/Set receive mode.
1 = ON (receiver enabled)
0 = OFF (receiver disabled)
Get receive mode:
RCV<CR>
Returns:
RCV Z<CR>
Set receive mode:
RCV Z<CR>
Returns:
RCV Z<CR>
RSS….. Get the receive signal strength.
Returns a value from 0- 10230
Get RSSI:
RSS<CR>
Returns:
RSS Z<CR>
Conversion
dBm = 0.0106 * Z 150dBm
RST…… Reset the unit. No return string.
Reset the unit:
RST<CR>
Returns:
SAV …... Save the current parameters in flash memory. Use this to store any parameter changes.
Save current settings:
SAV<CR>
Returns:
SAV MCDT DATA<CR>
SLP……. Shut down the serial port immediately to conserve power.
Enter low power mode:
SLP<CR>
Returns:
SLP<CR>
SRN…. Get the unit serial number.
The serial number is a string up to 20 characters long.
dBm
RSS value
-91
5284
-101
4523
-111
3570
-121
2591