Instruction Manual
QTI Page 11 of 13 Revision: A
Form #: 30Z0250 Effective Date: 16 December 2009
Section 4: Maintenance
OPERATOR MAINTENANCE:
The MCDT has been designed as low cost low maintenance equipment. All components are conformal coated
which reduces the amount of maintenance required. The only required operator maintenance is to inspect the
equipment for damage and keep the equipment clean of dirt, grime, and caked on mud.
NOTE: Do not submerge the equipment in water. This could result in damage.
DEPOT MAINTENANCE:
Upper echelon maintenance will be performed by the supplier of the equipment. If the equipment is beyond the
user capability to repair, it can be returned to the supplier for test and evaluation. Upon completion of the
inspection, the supplier will notify the user if the unit can be repaired. If the equipment is not covered by the
warranty, an estimate will be provided for repair costs. If the equipment is not repairable, the supplier will specify
replacement costs. (Note: See warranty below for return procedures.)
EQUIPMENT STORAGE:
Upon return to the facility, clean equipment as noted in operator maintenance above. Remove batteries from all
equipment to prevent possible damage. If batteries are left in the equipment, transmitters will continue to send fault
alarms every 10 minutes causing a continuous drain on the batteries and possibly resulting in damaged or ruptured
batteries. After cleaning, return the equipment to the storage cases. Store in a dry, room temperature environment.
WARRANTY:
Qual-Tron, Inc. guarantees all products to be free from defects in materials and workmanship for 12 months from
the date of purchase. Damage due to misuse, accidents, lightning strikes, unauthorized service, environmental
conditions beyond the equipment specifications, acts of war or damage other than fair, wear and tear is excluded
from this warranty.
RETURN PROCEDURES:
For support and service, please contact the following. To return any material, contact Qual-Tron, Inc. to receive a
Return Material Authorization (RMA) number. Once an RMA number has been assigned, ship the material to the
address below and reference the RMA number on the packing slip. Qual-Tron will return the equipment as quickly
as possible to the user.
QUAL-TRON, INC.
Attn: Sales Ph: 918-622-7052
9409 E. 55
th
Place Fax: 918-664-8557
Tulsa, OK 74145 email:
sales@qual-tron.com
TROUBLESHOOTING GUIDE:
Defect
Possible Cause
Corrective Action
Stage
Area
Empl
Site
Will not turn on
Battery low voltage
Check power supply
X
Does not
receive/transmit
alarms
Battery low voltage
Check power supply
X
Transmitter & receiver too
close to each other
Experiment with antenna combinations
(with & without)
X
X
Frequency
Verify transmitter and receiver are on
the same frequency
X
Receiver not enabled
Verify receive mode is on
X
Wrong message format
Check TRSS mode
X