SDS
SAFETY DATA SHEET
According to OSHA Hazard Communication Standard, 29 CFR
1910.1200
Version 1.3 Revision Date: 11/18/2015 Print Date: 01/07/2016
7 / 15 800001028739
US
necessary, prevent undissolved material from being dis-
charged to waste water. Waste water should be treated in a
municipal or industrial waste water treatment plant before
discharge to surface water.
Local guidelines on emission limits for volatile substances
must be observed for the discharge of exhaust air containing
vapour.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
: Liquid at room temperature.
Colour
: amber
Odour
: Slight hydrocarbon
Odour Threshold
: Data not available
pH
: Not applicable
pour point
: -45 °C / -49 °FMethod: ASTM D97
Initial boiling point and boiling
range
: > 280 °C / 536 °Festimated value(s)
Flash point
: 227 °C / 440 °F
Method: ASTM D93 (PMCC)
Evaporation rate
: Data not available
Flammability (solid, gas)
: Data not available
Upper explosion limit
: Typical 10 %(V)
Lower explosion limit
: Typical 1 %(V)
Vapour pressure
: < 0.5 Pa (20 °C / 68 °F)
estimated value(s)
Relative vapour density
: > 1estimated value(s)
Relative density
: 0.847 (15 °C / 59 °F)
Density
: 847 kg/m3 (15.0 °C / 59.0 °F)
Method: ASTM D287
Solubility(ies)
Water solubility
: negligible
Solubility in other solvents
: Data not available
Partition coefficient: n-
octanol/water
: Pow: > 6(based on information on similar products)