User Manual Part 3
User Guide to Q4000/QPRO
Document Number 1135-4713 Rev G
THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION OF QUAKE GLOBAL CORPORATION. IT MAY BE USED BY
RECIPIENT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED
BY RECIPIENT. DISCLOSURE TO UNAUTHORIZED THIRD PARTIES OR DUPLICATION WITHOUT THE EXPRESS WRITTEN PERMISSION OF QUAKE
GLOBAL IS PROHIBITED.
Page 76
CONFIDENTIAL
Information classified Confidential
-
Do not copy (See last page for obligations)
APL_init(void)
is the first application function called by the QUAKE firmware, and is the
starting point for custom code development. The statement: Quake Turnkey APL Version
Nov 30 2010, 09:54:30 indicates that the application is running properly and your
development environment is ready to begin developing custom applications.
12.2.4 Stopping and removing Turnkey from the modem
If an incorrect version of the application is downloaded and causes the modem to crash or reboot,
there is a command sequence to allow you to stop the modem and remove the application.
To stop the application:
1. Type ‘d’ ‘R’ on the Logger port to initiate a reboot.
2. Immediately press the 'x' key on the Logger Port during boot up until you get a prompt
asking: CANCEL LOAD OF CUSTOMER APPLICATION?. It may be necessary to press the
‘x’ key numerous times until you receive the prompt.
3. After the prompt, type ‘Yes’ (it is case-sensitive).
After that, the application is halted so that the file may be removed and a new application can
be downloaded into the modem