Data Sheet
Q4000 Technical Data Sheet
Document 1135-0902, REV K 13
IRIDIUM TX
N/A 0.950 0.470 0.350 11.200 8.33 mS burst
GlobalStar
Idle
N/A 1.5E-06 7.5E-07 5.6E-07 N/A Between TX burst
GlobalStar TX
0.198 0.095 0.038 0.028 0.896 1.44 S Burst
Note that these are average values. Maximum values may be as much as 15% more. All currents shown
above are individual contributions and at 25°C ambient. Items with burst or slot in the notes are the peak
values.
The power consumed by a GPS device remains constant. It will save power to turn off the GPS during
power down sequence. It takes about a minute after power on to get a GPS fix.
There are no software controllable lines gating power to these devices. The MTS has full flow control for
RS-232. You must ensure that whatever it is connected to is not drawing power from it
.
The use of Orbcomm and Iridium satellite network is not available when modem’s voltage drops below
10.5/7.5 VDC respectively.
Relay current is 1A MAX at 25C, .5A MAX at 85C. Power usage depends on customer application.
DC Input power to QUAKE Q4000 modems is +6.0V to +32.0VDC. Supplied input voltages outside this
range will result in damage to the modem and void the warranty.
Connector Information
2.5
Table 2-3, Q4000 Connector Types
Product
Q4000 Sat
Connect
Sat
Antenna
Connect
Q4000
GPS
Connect
GPS
Antenna
Connect
Q4000
GSM
Connect
GSM
Antenna
Connect
Q4000
Sat/GPS/Cellular
SMA-Female SMA-Male
GPS SMB
Jack
GPS SMB-
Plug
GSM
MCX-
Female
GSM
MCX-
Male