Owner`s manual

Page 11
Yosemite Wood Stove
R
7004-187I December 20, 2011
Minimum 16"
(406mm) from
fuel loading
door
8"(200mm)
USA
44-1/2"(1130mm) Minimum
36-3/4"
(932mm)
Minimum
Fuel loading doors
Front
Side
8"
(200mm)
Minimum 450mm
(18") from each
fuel loading door
CANADA
1187mm
(46-3/4")
Minimum
Fuel loading doors
Front
Side
200mm (8")
1264mm (49-3/4") Minimum
200mm
(8")
CANADA
200mm (8")
200mm
(8")
450mm (18")
1187mm
(46-3/4")
Minimum
1010mm (39-3/4")
Minimum
200mm
(8")
SIDE FUEL DOOR LOCKED SHUT
BOTH FUEL DOORS ACCESSIBLE
16" (406mm) from fuel
loading door
8"
(200mm)
USA
Front Fuel
loading door
33"(838mm) Minimum
36-3/4"
(933mm)
Minimum
10-1/2"
(267mm)
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-
combustible material, extending beneath heater and to the
front, sides and rear as indicated. The oor must be non-
combustible or otherwise adequately protected from radiant
heat given off by the unit and from sparks and falling embers.
A layer of thin brick or ceramic tile over a combustible oor
is not sufcient.
In US installations, i
t is necessary to install a oor protec-
tor a minimum of 16
inches (406mm) in front of glass and 8
inches (203mm) to both sides of the fuel loading door. Open
the door and measure 8 inches (203mm) from the side edge
of the opening in the face of the appliance. *See exception.
In Canada, similar oor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
*EXCEPTION: Non-combustible oor protections must
extend beneath the ue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 11.4.
4
Installation Considerations
WARNING
Fire Risk.
Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
Figure 11.1
Figure 11.2
Figure 11.3
Figure 11.4