EDGE 60 Pellet Fireplace
With proper installation, operation, and maintenance your appli-
ance will provide years of trouble-free service. This trouble-
shooting guide shall be used by a qualied service technician
only).
Error Message
Possible Cause Corrective Action
Bad wall control or control board
 wires have loose connections or installed
wrong
Replace wall control or control board
Check connections
BAD TC DROP TUBE
(TC
= Thermocouple)
Drop tube thermocouple is broken or leads are
reversed
Check connections
Replace thermocouple
BAD TC FIREPOT
(TC
= Thermocouple)
Firepot thermocouple is broken or leads are
reversed
Check connections
Replace thermocouple
SNAP DISC TRIPPED Overheat sensor (snap disc) has tripped
Convection blower may need cleaning
Turn power off to appliance and manually
reset snap disc then turn power back on
Clean convection blower if needed
VACUUM SW ERROR
(SW
= Switch)
Vacuum switch is bad
Vacuum hose is plugged/disconnected
Check connections. Bypass vacuum with
jumper wire, if runs, switch is bad. Replace
switch
Check vacuum hose
COMB BLOWER JAMMED Combustion blower is blocked/jammed Remove blockage
Replace blower if necessary
Turn the power switch OFF and then back
ON to clear the error
AUGER JAMMED Auger jammed, feed motor bad Pull the feed system and inspect
Clear jam and Press Retry
MISSED IGNITION Igniter bad or poor harness connection
Out of fuel or fuel is bridging in hopper
Faulty repot thermocouple connection has
shorted.
Check connections, if OK replace igniter
Break up bridging pellets
Rell hopper
Replace the thermocouple
Press Retry
MIN FIREPOT TEMP Out of fuel Rell hopper
Add handful of pellets to repot to prime it
Press Retry
MAX DROP TUBE TEMP Stove in over-heat condition
Flame height set too high
Components may need cleaning
Conrm setting matches burning fuel
Adjust ame height
Clean the rebox, heat exchanger, convec-
tion blower, repot and ash pan
CONV BLOWER JAMMED Convection blower blocked/jammed Remove blockage
Replace blower if necessary
Turn the power switch OFF and then back
ON to clear the error
CHECK ASHPAN Auto-clean jammed
Auto-clean switch is bad
Linkage has become disconnected
If ashpan is empty, check for a jam. Use a
screw driver and rmly push in the repot
oor holes and ex spring and push toward
home to release jam
Replace switch
Reconnect linkage
SCREEN GOES BLANK Static discharge or nearby lightening or
Electric fast transients at the input mains
W
ait 5 seconds and press any key to
refresh the screen.
Hopper lid not closed all the way
Switch is out of adjustment (auger will not
function)
Close the lid. If that didn’t work replae the
switch
Adjust or replace switch
Firebox door is not latched properly
Fireplace not rolled in completely
Adjust or replace door switch
Adjust or replace interlock switch
Out of fuel Check the latch, if OK replace switch
12
Troubleshooting For Installers