J. Fire Characteristics and Flame Height
Adjustment
A properly adjusted re will have an active ame pattern
and the ame will rise and fall somewhat. This is normal.
On HIGH setting, the ame will extend approximately 8
inches (0mm) out of the repot. If it is not 8 inches
(0mm) tall, increase the ame height.
On MEDIUM or LOW setting the ame will be shorter.
Reduce the ame height if the re has tall ames with
black tails and seems somewhat lazy. This may also
indicate that the repot and/or heat exchanger needs
to be cleaned. Refer to Section  for Maintenance and
Cleaning Instructions.
Adjusting the Flame Height
Set your appliance to “MANUAL” mode on the wall
control.
Set the heat output level to HIGH.
Adjust the ame height using the “FLAME HEIGHT
ADJUST” screen on the wall control. Figure 12.1.
Figure 12.1
K. Battery Back-up System (Optional)
The appliance has been designed to operate on an optional
battery back-up system.
If you have frequent power outages in your region, hook
the appliance up to a 1 volt battery and it will automatically
switch to battery power in the event of a power failure. The
1 volt power cord sold as a separate accessory does not
charge the battery.
13 Volts
12 Volts 11 Volts
Battery
Below
10 Volts
Figure 12.3
Operating on Battery Back-Up
A battery icon appears on your wall control to let you
know you are now operating on battery power. Figure
12.3
The re must be manually lit as the appliance will no
longer automatically light. Follow the instructions in the
Wall Control Manual.
Use only approved re starting gel to start the re.
The high burn rate is no longer available on battery
back-up.
Each level drops down one level, i.e the high burn be-
comes medium-high burn and so on.
If the battery charge falls below 10 volt it can no longer
sustain the appliance operation and the appliance will
shut down. You must disconnect and reconnect the bat-
tery to start it up again.
Recommended Battery
1 volt deep cycle battery, (i.e., marine or RV type).
A 1 volt battery cable is available through your local
dealer.
Instructions to Hook Up to Battery Back-Up
Open Front to expose battery plug on bottom left side of
replace. Plug in the battery. Figure 12.2 Be sure the bolt
securing the unit in place is installed and secure.
Firebox Door
Ash Door
Left Side
Battery Plug In
Figure 12.2
WARNING! Risk of Injury!
Do not operate in the battery back mode with the appli-
ance pulled out on the slides.
Blowers may continue to run and would be exposed to
human contact.