Owner`s manual
Page 10
7051-158
April 9, 2009
R
EDGE 60 Pellet Fireplace
R
R
G. Filling the Hopper with Fuel
NOTICE: RAISED PLATFORM INSTALLATIONS
Consideration must be given for lling the hopper with fuel
when determining the height of the raised platform. It must
not be so high that it interferes with the safety of lling the
hopper with fuel.
1. Start-Up Cycle
During this cycle:
• Igniter turns on for 90 seconds to heat up the air in the
repot
• Combustion blower starts
• Vacuum switch comes on
• Feed motor turns on adding fuel to the repot and the
appliance waits for the re to start
The duration of start-up depends on the type and quality
of fuel used. It is normal to see some smoke during the
ignition process as moisture evaporates and the fuel lights.
The smoke will stop once the re starts.
If you are lighting your appliance for the rst time:
• The feed tube will be empty and it can take some time to
ll it with fuel before you will see a re
• Put a handful of fuel in the repot (priming) to speed up
the process. You can also do this when you have run
completely out of fuel.
H. Starting Your First Fire
1. Fuel Selection
To start your rst re, you must:
• Select the appropriate fuel on the FUEL SELECTION
screen on the thermostat wall control to match the fuel
you have chosen to burn.
• If the proper fuel is not selected your appliance will not
operate properly.
• For example, if you have selected wood pellets and you
are burning corn, the appliance may not light, it may go
out or overfeed. Figure 10.1.
Sunflower Seeds
Corn
Utility Pellet
Softwood Pellet
Wheat
Hardwood Pellet
DONE
SELECT
FUEL SELECTION
I. Ignition Cycles
The replace engine is controlled by the digital thermostat
wall control. The digital display on the wall control will tell
you what your appliance is doing in the upper left corner
(System Status). Figure 10.3.
READY
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
System Status
Every time the thermostat calls for heat, the appliance steps
through ve cycles:
1 Start-Up Cycle 4 Shutdown Cycle
2 Soft-Start Cycle 5 Auto-Clean Cycle
Heating Cycle
The duration and characteristics of these cycles may be dif-
ferent with each type of fuel selected.
2. Comfort Level Selection
Once your fuel is selected, select the temperature at the desired
setting on the SET COMFORT LEVEL screen. Figure 10.2.
3. Automatic or Manual Setting
The automatic setting will control the heat output based on
the comfort level selection. The manual setting allows you
to manually control the heat output settings.
Figure 10.2
Figure 10.3
Figure 10.1
WARNING! RISK OF FIRE!
Do NOT
operate appliance:
• With appliance door open.
• Withrepotooropen.
• With ash pan removed
Check the hopper and make sure it is empty before lling
with fuel. Open the front to expose the hopper door. Pull
down on the hopper door to open and ll with fuel.