Quadra-Fire • SAPH-MBK-IPI, SAPH-D-PMH-IPI, SAPH-D-MBK-IPI, SAPH-D-CSB-IPI Installation Manual • 2343-980_R8 • 11/1443
Figure 7.18 Venting through the wall
Note: When using termination caps with factory-supplied
Install Horizontal Termination Cap
WARNING! Risk of Fire! The telescoping ue section of the
termination cap MUST be used when connecting vent.
• 1-1/2 (38 mm) minimum overlap of ue telescoping section
is required. Failure to maintain overlap may cause
overheating and re.
location guidelines as prescribed by current ANSI Z223.1
and CAN/CGA-B149 installation codes and refer to
CAUTION! Risk of Burns! Local codes may require
installation of a cap shield to prevent anything or anyone
from touching the hot cap.
NOTICE: For certain exposures which require superior
resistance to wind-driven rain penetration, a ashing kit and
HRC caps are available. When penetrating a brick wall, a
brick extension kit is available for framing the brick.
INTERIOR
HEAT SHIELD OR
EXTENDED
HEAT SHIELD
WALL SHIELD
FIRESTOP
SHEATHING
VENT DEPTH FROM BACK OF APPLIANCE TO
OUTSIDE SURFACE OF EXTERIOR WALL
(SEE CHART BELOW)
SLIP SECTION
CAN BE EXTENDED
INNER VENT
OUTER VENT
EXTERIOR