Owner`s manual

Page32
December 1, 2011
Santa Fe NZ Pellet Stove
R
7068-114B
6. Fuse
Thefuseislocatedonthesideofthejunctionboxabove
totheredcalllight.Thefusewillblowshouldashortoccur
andshutoffpowertotheappliance.
7. Heat Output Switch
Theheatoutputswitchislocatedontheupperrightback
panel.Thefunctionoftheheatoutputswitchistoregulate
theburnrates;low,mediumandhighsettings.
8. Hopper Switch
Thehopperswitchislocatedintheupperrighthandcorner
ofthehopper.Thisswitchisdesignedtoshutdownthe
feedmotorwheneverthehopperlidisopened.
9. Igniter
Theigniterismountedonthebaseoftherepot.
Combustionairtravelsovertheredhotignitercreating
superheatedairthatignitesthepellets.
10. Junction Box And Wiring Harness
Thejunctionboxislocatedonthelowerleftsideofthe
appliance,behindtheleftsidepanel.Thejunctionboxand
wiringharnessarereplacedasonecomponent.
11. Power Supply
Thepoweroutletislocatedbehindthecontrolboxonthe
backoftheappliance,lowerleftcorner.Checkthewall
receptaclefor230volt,50Hz(standardcurrent).Make
suretheoutletisgroundedandhasthecorrectpolarity.A
goodsurgeprotectorisrecommended.
12. Red Call Light
Theredcalllightisonthesideofthejunctionbox,below
thefuse.Thefunctionoftheredcalllightistoindicatethat
thethermostatiscallingforheat.
13. Reset Button
Theresetbuttonislocatedonthebackoftheappliancein
theupperrightcornerbelowtheheatoutputcontrolswitch.
Thefunctionofthebuttonistomomentarilyopenthe
thermostatcircuit,whichrestartsthesystem.
14. Thermocouple
Thethermocoupleislocatedontopoftherepotinside
thethermocouplecover(ceramicprotectiontube).The
thermocouplesendsamillivoltsignaltothecontrolbox
indicatingthepresettemperaturesofthegreenandred
lightshavebeenobtained.
15. Thermostat (Optional)
Theappliancehastheoptiontoberunoffathermostat.For
theTheheatanticipatorshouldbesetonthelowestsetting
available.
16. Snap Disc #1 (Convection Blower) 43°C
Snapdisc#1islocatedontherightsideoftheappliance
behindtherightsidepanel.Thereare2purplewires
connectedtoit.Thissnapdiscturnstheconvectionblower
onandoffasneeded.Powerisalwayspresentatsnapdisc
#1.
17. Snap Disc #2 (Fuel Delivery Interrupt) 79°C
Snapdisc#2islocatedonthecentreoftheconvection
plenumabovetheconvectionblower.Thereisanorange
andablackwireconnectedtoit.Thissnapdiscwillturn
offthefeedsystemwhichwillturnofftheapplianceif
anoverreconditionshouldoccuroriftheconvection
blowershouldfailtooperate.Ifthisoccursyouwillhaveto
manuallyresetthesnapdisc.
18. Snap Disc #3 (Back Burn Protector) 121°C
Snapdisc#3ismountedonthebackoftheaugertubein
thecentreoftheapplianceandhasaresetbutton.There
aretwogreywiresconnectedtoit.Toaccessitremovethe
rightsidepanel.Iftheretriestoburnbackintothefeed
systemorpushexhaustupthefeedtube,thissnapdisc
willshuttheentiresystemoff.Thisdiscmustbemanually
reset.
19. Vacuum Switch
Thevacuumswitchislocatedonthelowerrightsideofthe
appliancebehindrightsidepanel.Therearetworedwires
attachedtoit.Thisswitchturnsthefeedsystemonwhen
vacuumispresentintherebox.Thevacuumswitchisa
safetydevicetoshutoffthefeedmotoriftheexhaustorthe
heatexchangersystemisdirtyorpluggedoriftherebox
doorisopen.