Owner`s manual

R
May 12, 2014
7019-221F
Page 15
Santa Fe Pellet Insert
C. Full Reline With Outside Air - Vertical
Figure 15.3
NOTE: Check clearances carefully for this type of
installation to ensure adequate room for outside air
venting.
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult local building, re of cials or authorities having
jurisdiction about restrictions, installation inspection,
and permits.
CAUTION
Direct Connect
45 degree elbow
Side view of Santa Fe Insert with
side panel removed.
Figure 15.1
Figure 15.2
NOTE: In Canada, only a full reline is allowed per ULC
S628-93, ORD ULC C1482-M1990.
NOTE: In Canada this replace insert must be installed
with a continous chimney liner a 6 inch (152mm) in diam-
eter extending from the replace insert to the top of the
chimney. The chimney liner must conform to the Class 3
requirments of CAN/ULC-S635, Standard for Lining Sys-
tems for Extising Masonry or Factory-Built Chimneys and
Vents, or CAN/ULC-S640, Standard for Lining Systems
for New Masonry Chimneys.
Outside Air
Termination
at
Chimney Top
12” (305mm)
min. below
12” (305mm)
min. above
NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.
Do not use high
temperature caulk-
ing materials to seal
any edge to prevent
future serviceability