User manual
Page22
October 27, 2011
R
Castile & Santa Fe CE Insert
7069-101B
Do not terminate ventinanyenclosedorsemi-enclosed
areasuchasacarport,garage,attic,crawlspace,undera
sundeckorporch,narrowwalkwayorcloselyfencedarea,
oranylocationthatcanbuildupaconcentrationoffumes
suchasastairwell,coveredbreezeway,etc.
CAUTION
A. Venting Termination Requirements
1. Terminationmustexhaustaboveairinletelevation. It is
strongly recommended that at least 1.5m of vertical
pipe be installed when appliance is vented directly
through a wall.Thiswillcreateanaturaldraft,which
willhelppreventthepossibilityofsmokeorodorventing
intothehomeduringapoweroutage.Itwillalsokeep
exhaustfromcausinganuisanceorhazardbyexposing
peopleorshrubstohightemperatures.Thesafestand
preferredventingmethodistoextendtheventvertically
throughtheroof.
2. Distancefrom doorsandopeningwindows,orgravityor
ventilationairinletsintobuilding:
a. Notlessthan1.2mbelow;
b. Notlessthan1.2mhorizontallyfrom;
c. Notlessthan305mmabove.
3. Distancefrompermanentlyclosedwindows;
a.Not less than 305mm below; horizontally from or
above.
4. Distancebetween bottomofterminationandgradeshould
be305mmminimum.Thisisconditionaluponplantsin
thearea,andnatureofgradesurface.Thegradesur-
facemustbeanon-combustiblematerial(i.e.,rock,dirt).
Thegradesurfacemustnotbelawn.Distancebetween
bottom of termination and public walkway should be
2.13mminimum.
5. Distance to combustible materials must be 610mm
minimum. This includes adjacent buildings, fences,
protrudingpartsofthestructure,roofoverhang,plants
andshrubs,etc.
6. TerminationCapLocation(HomeElectricalService)
• Side-to-sideclearanceistobethesameasminimum
clearancetovinylinsidecorners.
• Clearanceofaterminationcapbelowelectricalservice
shallbethesameasminimumclearancetovinylsofts.
• Clearanceofaterminationcapaboveelectricalservice
willbe305mmminimum.
• Locationoftheventterminationmustnotobstructor
interferewithaccesstotheelectricalservice.
7
Vent Information
B. Avoiding Smoke and Odors
Negative Pressure, Shut-Down and Electrical Power
Failure
Toreducetheprobabilityofback-draftingorburn-backin
thepelletapplianceduringpowerfailureorshutdowncon-
ditions,it must be able to draft naturally withoutexhaust
bloweroperation.
Negativepressureinthehousewillresistthisnaturaldraft
ifnotaccountedforinthepelletapplianceinstallation.
Heatrisesinthehouseandleaksoutatupperlevels.This
air must be replaced with cold air from outdoors which
owsintolowerlevelsofthehouse.
Ventsandchimneysintobasementsandlowerlevelsofthe
housecanbecometheconduitforairsupplyandreverse
undertheseconditions.
Outside Air
Anoutsideairkitisrecommendedinallinstallations.The
OutsideAirKitmustbeorderedseperately.
Peryourlocalbuildingcodes,considerationmustbegiven
to combustion air supply to all combustion appliances.
Failuretosupplyadequatecombustionairforallappliance
demands may lead to backdrafting of those and other
appliances.
Whentheapplianceisroofvented(stronglyrecommended):
The air intake is bestlocated onthe exteriorwall ori-
entedtowardstheprevailingwind direction duringthe
heatingseason.
Whentheapplianceisside-wallvented:
Theairintakeisbestlocatedonthesameexteriorwall
astheexhaustventoutletandlocatedloweronthewall
thantheexhaustventoutlet.
Theoutsideairsupplykitcansupplymostofthedemands
ofthepelletappliance,butconsiderationmustbegivento
thetotalhousedemand.
Housedemandmayconsumetheairneededfortheappli-
ance.Itmaybenecessarytoaddadditionalventilationto
thespaceinwhichthepelletapplianceislocated.
Consultwithyourlocalheatingprofessionaltodetermine
theventilationdemandsforyourhouse.