Installation manual

16 7019-230A 6/27/2014
Santa Fe Pellet Insert
B. Full Reline With Outside Air - Vertical
Figure 16.3
NOTE: Check clearances carefully for this type of instal-
lation to ensure adequate room for outside air venting.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
Consult local building, re of cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
CAUTION
Direct Connect
45 degree elbow
Side view of Santa Fe Insert with side panel
removed.
Figure 16.1
Figure 16.2
NOTE: In Canada, only a full reline is allowed per ULC
S628-93, ORD ULC C1482-M1990.
NOTE: In Canada this replace insert must be installed
with a continuous chimney liner a 6 inch (152mm) in diam-
eter extending from the replace insert to the top of the
chimney. The chimney liner must conform to the Class 3
requirements of CAN/ULC-S635, Standard for Lining Sys-
tems for Existing Masonry or Factory-Built Chimneys and
Vents, or CAN/ULC-S640, Standard for Lining Systems
for New Masonry Chimneys.
Outside Air
Termination
at
Chimney Top
12” (305mm)
min. below
12” (305mm)
min. above
NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.
Do not use high
temperature caulk-
ing materials to seal
any edge to prevent
future serviceability