Installation manual

10 7019-230A 6/27/2014
Santa Fe Pellet Insert
Mark area of
floor to cut
Starter hole
Keep sharp edge of
metal floor away from
power cord
H.
Removing Metal Floor of Factory-Built Fire-
box
• The rebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory-built
rebox in order to gain minimum insert opening require-
ments.
Any smoke shelves, shields and baf es may be removed
from a factory-built rebox if attached with mechanical fas-
teners.
• The metal oor of the factory-built rebox may be removed
to facilitate the installation of the insert only when a 1/4
(6mm) inch airspace is provided between the insert and the
oor of outer wrap.
The following is only one example as there are many different
models of factory-built replaces.
Figure 10.1. Measure and mark the metal oor for cutting. With
a drill, make a starter hole in each corner.
Figure 10.2. Using a saws-all, cut out the oor.
Figure 10.3. Ensure that the power cord can not be damaged
by the sharp metal edge. You may need to cut out a notch to
accommodate the cord.
NOTE: If the oor is made of thin metal, we recommend using
the 2 x 4 from the insert packaging to support the insert. The
2 x 4 may need to be cut to the appropriate size. Ensure that
the leveling leg is positioned over the 2 x 4 before leveling the
insert.
I. Altering the Factory-Built Fireplace
The replace must not be altered, except for the exceptions
listed below. Do not removal the bricks and mortar from
the existing replace.
The following modi cations are permissible:
Removal of damper or locked in open position
Removal of smoke shelf or baf e
Removal of ember catches
Removal of re grate
Removal of view screen/curtain
Removal of doors
• External trim pieces which do not affect the operation of
the replace may be removed providing they can be stored
on or within the replace for reassembly if the insert is
removed.
The permanent metal warning label provided must be
attached to the back of the replace, with screws or
nails, stating that the replace may have been altered to
accommodate the insert, and must be returned to original
condition for use as a conventional replace. Figure 10.4.
If the hearth extension is lower than the replace opening,
the portion of the insert extending onto the hearth must
be supported.
Manufacturer designed adjustable support kit can be
ordered from your dealer.
Final approval of this installation type is contingent upon
the authority having jurisdiction.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation into
replaces without a permit will void the listing
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Figure 10.4