Step 4. Positioning, Leveling, and
Securing the Fireplace
Place the fireplace into position.
Level the fireplace from side to side and from front to
back.
Shim the fireplace with noncombustible material, such
as sheet metal, as necessary.
Secure the fireplace to the framing by nailing or screwing.
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 30. Proper Positioning, Leveling, and
Securing of a Fireplace
Figure 31. Gas Control System
STANDING PILOT
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
This model fireplace uses a Standing Pilot Ignition system.
This system includes millivolt control valve, standing pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING: 110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.