HIGH ALTITUDE OPERATION
In Canada, this unit is approved from 0 to 4500 feet above
sea level. Installation of this stove at altitudes above 4500
feet is subject to eld test of the individual installation and
approval by the local authority having jurisdiction.
In the United States, input ratings of this unit are based
on sea level operation, and shall not be changed for operation
at elevations up to 2000 feet. For operation at elevations
above 2000 feet, this stove shall be reduced at the rate of
4% for each 1000 feet above sea level.
Exception: As permitted by the authority having jurisdiction.
To adjust stove for operation above 2000 feet the burner
orices may need to be changed. The orices are located
beneath the log set so it is necessary to rst remove the logs.
To do so please refer to the following detailed instructions to
achieve optimum performance of your stove.
WARNING ! The following procedure should only be
undertaken by a qualied and certied gas appliance
installer.
CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND
TURN OFF GAS SUPPLY TO UNIT BEFORE PROCEED-
ING.
1. If logset is installed, remove logs, lava rock and
embers.
2. With a Phillips screwdriver, remove seven screws (3 in
front and 2 on each side), and lift out burner tray.
3. Remove the two Phillips head screws that secure the
burner pan in place.
4. Remove the burner pan by sliding to the right and
lifting out. (Shutters may need to be adjusted ‘closed’
to make this easier).
5. Slide shutters out of the way. Using a 5/8" wrench
or socket, remove the orice and replace with proper
orice for the specied gas. See below.
6. Reinstall burner pans and adjust shutters to ‘open’
position.
CAUTION: The correct orice placement is critical for
proper appliance performance follow BTU
de-rating chart below to locate the necessary
orice size for the front and rear burners.
OPERATION
Read this entire manual prior to using the replace. Pay
particular attention to the Safety Precautions” section on
pages 6-9. Failure to follow the instructions may result in
property damage, bodily injury, or even death.
MAIN BURNER ..................This control is used to turn the
replace on and off.
PILOT IGNITOR ................ The pilot ignitor is used only to
start the pilot. When pressed, it sends an electrical charge to
the pilot assembly. This creates a blue spark directly next to
the pilot, igniting the pilot ame.
VALVE CONTROL .............This knob is used to control gas
to the replace and for starting the pilot. There are three
positions, ON, OFF, & PILOT. The pointer on the panel
indicates the position of the knob.
COMFORT CONTROL....... This knob controls the ame height
from low (“LO”) to high (“HI”).
FAN SPEED ....................... This knob controls the speed of
the internal convection blower that pushes the heated air
into the room.
NOTE: If using a remote control or thermostat, the On/Off
Switch must be left “OFF”. Turning the On/Off Switch “ON”
will keep the replace on continually.
Orice size 2000 3000 4000 5000 6000 7000 8000 9000 10000
at Sea Level:
Natural Gas
Front 36 36 36 37 38 39 40 40 41 41
Propane
Front 52 52 52 52 53 53 53 54 54 54
equivalent orice sizes at high altitudes
(Includes 4% Input Reduction For Each 1000 Feet)
IGNITOR
MAIN
BURNER
FAN
SPEED
VALVE
CONTROL
THERMOSTAT
CONECTION
COMFORT
CONTROL
OPERATION