QFP 30 Direct Vent Gas Fireplace
LEAK TEST
1. Turn on gas to the replace.
2. Turn on gas at the manual shutoff valve.
3. Leak test all gas joints prior to starting the appliance.
4. Familiarize yourself with the control panel components,
see page 36.
5. Follow Lighting Instructions on next page to light the
pilot and then the main burner.
6. Leak test all gas joints again.
7. Check the pilot ame ensuring that it looks like the
illustration below. Adjust the pilot ame if necessary.
WARNING! You must clean all
ngerprints and oils from any gold
surface prior to ring the replace
for the rst time.
PILOT HOOD
FLAME
FLAME
MILLIVOLT
GENERATOR
THERMOCOUPLE
INITIAL START-UP:
NORMAL OCCURRENCES
Fumes from curing paint and oil burning off the steel is a
normal occurrence. Open window to vent the area until
fumes disappear.
Condensation appearing on the glass each time you start
the replace is also normal.
Blue Flames will occur on the initial start-up. After fteen
minutes the flames will become the yellow/orange
ame color.
Remote Wall Switch: If you install a remote wall switch to
operate the replace, leave the ON/OFF switch on the
replace control panel in the “ON” position.
• Do not place any combustible items on top of or
directly in front of the replace, even temporarily.
The optional thermostat may start the replace
causing a combustible item to ignite.
• If the replace turns on and off frequently while
using the thermostat, you may
want to adjust
the flame height down until it produces just
enough heat needed, or relocate the thermostat
further away from the replace.