Specifications
QFP 30 Direct Vent Gas Fireplace
Page 32 03/21/01 #250-6120
INSTALLING GLASS
Use only Part #842-3821, Replacement Glass, available from your dealer to replace glass in the QFP 30 Fireplace.
To install the glass assembly, lift and set the bottom extensions onto the bottom alignment slots located at the
edge of rebox--refer to diagram below. With the bottom edge of door/glass assembly resting on the bottom alignment
pins, lift door/glass up and onto the top alignment slots. Secure the door/glass assembly to zc appliance with the spring
latches, two on top and two at bottom.
INSTALLING FASCIA
All fascias attach to four bolt openings located twoper side on the door/glass frame. Insert and nger start bolts tightening
with the 5/32" Allen wrench supplied with unit.
CAUTION: Use care in handling of glass assembly, do
not strike or slam as this could cause breakage.
GLASS & FASCIA INSTALLATION
Insert bolts through these
holes and into flanges shown
in glass install drawing.
(2 per side)
SPRING LATCHES
(2 upper & 2 lower)
Flanges for setting
glass onto alighment
slots. (2 per side)
Alignment Slots
(2 per side)