Specifications
QFP 30 Direct Vent Gas Fireplace
Page 14 03/21/01 #250-6120
INSTALLATION
HEARTH REQUIREMENTS
MANTEL REQUIREMENTS
No clearances to combustible ooring or hearth extension are
required for installatoin of the QFP30, as referenced in the
Clearances to Combustibles label on page 6 of this manual
and the Clearances tag on the unit.
NOTE: Ensure the depth of your flooring material does
not exceed the 1” height at bottom front ange of the ZC
Appliance, illustrated below. Clearance of this area is
necessary in order to allow freedom of movemenet of the
control panel access door when the fascia is installed later.
COMBUSTIBLE MANTELS
See also references on page 6, Clearances to Combustible
Materials label.
The allowable height from the bottom of the unit to the lower
edge of a maximum mantel depth of 12”, is 48”.
The allowable height from the bottom of the unit to a maxi-
mum combustible trim width of 2-1/4”, is 43-1/2”.
1"
Flooring (tile, wood, carpet)
must lie beneath this edge.
Left side of ZC
Appliance
Right side of ZC
Appliance
43-1/2"
48"
Trim
Mantel
Mantel clearances
from bottom of ZC
appliance to lower
edge of mantel or trim.