C. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3-inch exible vent pipe(s) down through the
chimney.
Secure the exhaust exible vent pipe to the 3 foot section
stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 8.1).
Secure the stainless exible vent pipe to the exhaust
starting collar on top of the appliance with three screws.
Use 3 screws to attach the section of inlet air vent to
the inlet collar on the collar slide plate. See Figure 8.1.
NOTE: The collar slide plate may be removed from
appliance to aid installation.
Figure 8.2
CUT AND BEND
FLASHING AS NEEDED
TO FIT CHIMNEY
SEALANT
ADHESIVE
Trim chimney top plate to minimize excess overhang or
bend over ue tile (see Figure 8.2).
Place 3/8 inch bead of silicone (300ºF minimum
continuous exposure rating) on ue tile top.