Owner`s manual
19Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
Figure 5.2 Fireplace Opening
In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).
E
FRONT VIEW
D
C
F
A
TOP VIEW
B
G**
H
MINIMUM FIREPLACE SIZE
Location
QFI35FB-C QFI30FB-C
Inches Millimeters Inches Millimeters
A Rear Width 25-1/2 648 21-1/2 546
B Front Width 35 889 30-1/4 768
C Glass Opening Width 31-1/2 800 26-3/4 679
D Glass Opening Height 20 508 18 457
E Height-Front 24-7/8 632 22-7/8 581
F Height-Rear 22-1/4 565 20-5/8 524
G** Unit Depth 18-1/4 464 16-7/8 429
H Venting Depth 13-3/8 340 12-1/8 308
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum