Fireplace Size Requirements
A. Minimum Fireplace Opening
Minimum replace opening requirements for a standard 3/4
inch deep surround are shown in Figure 5.2. For smaller
openings, an optional 1-1/2 inch deep surround is available
and dimensions are shown in Figure 5.3.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
• The rebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory
built rebox in order to gain minimum gas insert opening
requirements.
Any smoke shelves, shields and baf es may be removed
from the factory built rebox if attached with mechanical
fasteners.
• The metal oor of the solid fuel rebox may be removed
to facilitate the installation of the insert.
Cutting of any sheet metal parts of the replace in which
the gas replace insert is to be installed is prohibited,
except the oor as tested for and as noted above and in
Figure 5.1.
A minimum 1/2 inch gap from the bottom of the
appliance to the metal oor of the solid fuel rebox is
RECOMMENDED for optimal fan performance. See
side view in Figure 5.1
Figure 5.1-A
SIDE VIEW
6 IN.
5 IN.
3 IN.
9 IN.
METAL INSERT
FACTORY BUILT FIREBOX
6 IN.
5 IN.
3 IN.
9 IN.
METAL FLOOR OF EXISTING
SOLID FUEL FIREBOX
TOP VIEW
REMOVE THIS
SECTION OF
METAL FLOOR
REMOVE THIS
SECTION OF
METAL FLOOR
1/2 IN. MINIMUM LEVELING HEIGHT
(RECOMMENDED)
1/4 IN. REQUIRED
METAL FLOOR OF EXISTING SOLID FUEL FIREBOX
The appliance may not be placed directly on the base of
the outer wrap, a 1/4 inch airspace MUST be provided
between the insert and the oor of the outer wrap. Use
the leveling legs to raise the insert a minimum of 1/4 inch.
The original replace may never be returned to solid
fuel in this condition. The sidewalls and top structure
of the rebox may not be altered with the exception of
removable baf es and dampers.
If a minimum 1/2 inch gap can not be achieved, a section
of the factory-built metal oor can be removed. See
Figure 5.1-B.
Figure 5.1-B