Owner`s manual
Page 12
7014-188G
November 5, 2014
R
1200-I Pellet Insert
Mark area of
floor to cut
Starter hole
Use 2 x 4 from insert
packaging to support insert
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Figure 12.1
• Removing fl oor of fi replace must not weaken structure
of fi rebox or reduce protection for combustible materials.
• Final approval of this installation type is contingent upon
the appropriate local authority having jurisdiction.
WARNING
J. Installation into a Masonry Fireplace
All modifi cations that can be made to a Factory Built Fire-
place can be made to a Masonry Fireplace.
In addition DO NOT remove any brick or mortar from the
existing fi replace.
I. Installation into a Factory-Built Fireplace
The following modifi cations are permissible:
• Removal of damper or locked in open position
• Removal of smoke shelf or baffl e
• Removal of ember catches
• Removel of fi re grate
• Removal of view screen/curtain
• Removal of doors
• Removal of factory-built fi replace fl oor
• External trim pieces which do not affect the operation of
the fi replace may be removed providing they can be stored
on or within the fi replace for reassembly if the insert is
removed.
• The permanent metal warning label provided must be
attached to the back of the fi replace, with screws or
nails, stating that the fi replace may have been altered to
accommodate the insert, and must be returned to original
condition for use as a conventional fi replace. Figure 12.1
• If the hearth extension is lower than the fi replace opening,
the portion of the insert extending onto the hearth must
be supported.
• Manufacturer designed adjustable support kit can be
ordered from your dealer.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation
into fi replaces without a permit will void the listing.•
• The fi rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory-built fi rebox in order to gain minimum insert
opening requirements.
• Any smoke shelves, shields and baffl es may be removed
from a factory-built fi rebox if attached with mechanical
fasteners.
• The metal fl oor of the factory-built fi rebox may be
removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between the
insert and the fl oor of outer wrap.