Owner`s manual

Page 12
7014-188G
November 5, 2014
R
1200-I Pellet Insert
Mark area of
floor to cut
Starter hole
Use 2 x 4 from insert
packaging to support insert
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Figure 12.1
• Removing oor of replace must not weaken structure
of rebox or reduce protection for combustible materials.
Final approval of this installation type is contingent upon
the appropriate local authority having jurisdiction.
WARNING
J. Installation into a Masonry Fireplace
All modi cations that can be made to a Factory Built Fire-
place can be made to a Masonry Fireplace.
In addition DO NOT remove any brick or mortar from the
existing replace.
I. Installation into a Factory-Built Fireplace
The following modi cations are permissible:
Removal of damper or locked in open position
Removal of smoke shelf or baf e
Removal of ember catches
Removel of re grate
Removal of view screen/curtain
Removal of doors
Removal of factory-built replace oor
• External trim pieces which do not affect the operation of
the replace may be removed providing they can be stored
on or within the replace for reassembly if the insert is
removed.
The permanent metal warning label provided must be
attached to the back of the replace, with screws or
nails, stating that the replace may have been altered to
accommodate the insert, and must be returned to original
condition for use as a conventional replace. Figure 12.1
If the hearth extension is lower than the replace opening,
the portion of the insert extending onto the hearth must
be supported.
Manufacturer designed adjustable support kit can be
ordered from your dealer.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation
into replaces without a permit will void the listing.
• The rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory-built rebox in order to gain minimum insert
opening requirements.
Any smoke shelves, shields and baf es may be removed
from a factory-built rebox if attached with mechanical
fasteners.
• The metal oor of the factory-built rebox may be
removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between the
insert and the oor of outer wrap.