Installation manual
June 19, 2014 7036-188C 17
MT VERNON AE INSERT
NOTE: Check clearances carefully for this type of instal-
lation to ensure adequate room for outside air venting.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
CAUTION
NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482-M1990.
B. Full Reline With Outside Air - Vertical
Figure 17.1
Outside Air
Termination
at
Chimney Top
(Vertical)
305mm min.
below
305mm min.
above
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insula-
tion such as fiberglass, mineral
wool or ceramic.
Do not use high temperature caulk-
ing materials to seal any edge to
prevent furture serviceability.
NOTE: In Canada this fi replace insert must be installed
with a continuous chimney liner of 6 inch (152mm) diam-
eter extending from the fi replace insert to the top of the
chimney. The chimney liner must conform to the Class
3 requirements of CAN/ULC-S635, Standard for Lining
Systems for Existing Masonry or Factory-Built Chimneys
and Vents, or CAN/ULC-S640, Standard for Lining Sys-
tems for New Masonry Chimneys.