C. General Information About Using the Wall
Control
Whenabuttonispressedandthescreenchangesfromthe
mainscreentooneoftheotherscreens,thebacklightwillil-
luminatethedisplayarea.Asbuttonsarepressed,theback-
lightcontinuestobeilluminated.
Most screens have a DONE button which can be used to
returntothepreviousscreenultimatelyreturningtothemain
screen.
Thewallcontrolwillautomaticallyrevertbacktothestarting
screenifthereisnoactivityfor15secondsexceptforthe
COMFIRMFUELCHANGEscreen.Themainscreenwillbe
illuminated for an additional 10 seconds and thebacklight
willshutoff.
Ifthewallcontrolissubjectedtoastaticshock,thescreen
maygoblank.Ifthishappens,wait25secondsandpress
anybutton.Thiswillresetthescreenrestorefunctionality
andturnonthebacklight.Ifthisdoesnotwork,callyour
dealer.
D. The Main Menu
Themenuis the heart ofcustomizingtheoperation of the
pelletappliancesystemtoyourpersonalliking.Thechoices
onthismenuare:
Auto/Manual/Off
User Settings
Fuel Type
MENU
Set Comfort Level
Program
Set Date
Service Info
MENU
Set Day/Time
Figure 3.1
5. Function Buttons
Thefunctionbuttonshavetwolabelsabovetheminthedis-
playarea.Theirlabelscanchangedependingonthemenu
screen.Onthemainscreentheleftbuttonwillbringupthe
systemmenuandtherightbuttonhasfunctionalityonlyin
MANUALcycle.Figure 3.2.
6. Current Temperature
Thecurrenttemperatureareaindicatesthetemperatureof
the room where the wall control is located. The tempera-
turedisplayedcanbeinunitsofFahrenheitorCelsius.The
desired units can be selected via the system menu. See
Figure 6.5 on page 6.
1. Set Comfort Level (Temperature)
The most basicoperation ofthe wall control is to turn the
applianceonoroffdependingontherequirementforheat.
Fromthemainscreen,theSETCOMFORTLEVELscreen
canbeactivatedbypressingtheUPorDOWNbuttononthe
rightsideofthedisplayarea.
Thersttimeeitherbuttonispressedthedisplaychangesto
theSETCOMFORTLEVELscreenandshowsthecurrent
settemperature.SubsequentpressesorholdingtheUPor
DOWNbuttonwillchangethesettemperature. Figure 3.2.
You can override the programming either permanently or
temporarily. The HOLDTEMP button (lower right) on the
SETCOMFORT LEVELscreen is used to override preset
programming. Figure 3.3. By pressingthe HOLDTEMP
button,thecurrentsettemperaturewillpermanentlyoverride
anyprogrammedtemperatureinthe7daysetbackprogram-
ming.Thisisaconvenientwayofoverridingaprogramwhen
your schedule changes temporarily and you don’t want to
reprogramthesetbackfunctionsonthewallcontrol.
Toreleasethepermanentoverride,pressthebuttonlabeled
RESUMEwhenintheHOLDTEMPcycle.Pressingthebut-
tonagainwillresumetheprogrammingatthenextprogram
interval.Figure 3.4.
To temporarilyoverride the programming, use theUPand
DOWNbuttonsonlyanddonotpresstheHOLDTEMPbut-
ton.Thedisplaywillshowhowlongthenewtemperaturewill
hold before it returns to the next scheduledprogramming.
Figure 3.3.
Figure 3.3
Figure 3.2
Function Buttons
Buttons
Up
Down
Figure 3.4